Lead-safe rules for window and siding work in homes built before 1978
What the EPA's lead-safe rule asks of a company replacing windows, doors or siding in an older home, and which states run their own certification.
On this page: 5 sections
Old paint can contain lead, and replacing windows, doors or siding can disturb a lot of it. A federal rule sets how companies have to work in homes built before 1978. Here's what it asks, and where a state runs the program itself.
Which homes it covers
The rule covers target housing: any housing built before 1978, except housing for the elderly or people with disabilities and homes with no separate bedroom, unless a child under 6 lives there or is expected to.1-2
The small-job exemption never covers window replacement
Small jobs that disturb only a little paint can be exempt as minor repair and maintenance: 6 square feet or less of painted surface per room inside, or 20 square feet or less outside. That exemption never applies to window replacement, even when the painted area is small.2
- Windows: a paid job replacing even one window in target housing is covered, unless the parts the job disturbs have been tested and found free of lead-based paint.3
- Doors: the rule's definition of renovation names changing painted doors. Taking out a painted door counts its whole painted surface toward the small-job limits, so a door replacement is nearly always covered.2
- Siding: removing painted siding is covered once more than 20 square feet of painted surface is disturbed, counting the whole of every piece taken off.2
What the company has to do
- Be certified. No firm may do, offer or claim to do renovations in target housing without certification.4-5
- Put a certified renovator in charge. A certified firm has to assign a certified renovator to each job, and the work has to follow lead-safe practices, with cleaning and a check of the cleaning at the end.5-6
- Give you the Renovate Right pamphlet. The firm has to give the owner the EPA's pamphlet no more than 60 days before work starts.7
States that run their own program
In most states the EPA certifies firms. Fifteen states run their own EPA-authorized program, and a firm working there gets its lead-safe certification from the state: Alabama, Delaware, Georgia, Iowa, Kansas, Massachusetts, Mississippi, North Carolina, Oklahoma, Oregon, Rhode Island, Utah, Vermont, Washington and Wisconsin.8
The state programs' own pages:
- Alabama Department of Public Health: lead
- Delaware Division of Public Health: lead information for contractors
- Georgia Environmental Protection Division: lead-based paint
- Iowa Department of Inspections, Appeals, and Licensing: lead
- Kansas Department of Health and Environment: lead licensing and certification
- Massachusetts Department of Labor Standards: Deleading and Lead Safety Program
- Mississippi Department of Environmental Quality: lead-based paint
- North Carolina Department of Health and Human Services: lead training and certification
- Oklahoma Department of Environmental Quality: lead-based paint
- Rhode Island Department of Health: lead safe renovation, repair and painting
- Oregon Health Authority: renovation, repair and painting rule
- Utah Department of Environmental Quality: lead-based paint program
- Vermont Department of Health: renovation, repair and painting
- Washington State Department of Commerce: renovation, repair and painting
- Wisconsin Department of Health Services: lead
What to ask before work starts
- Whether the company is a lead-safe certified firm, and who certified it: the EPA or your state.
- Who the certified renovator on your job will be.
- When you'll get the Renovate Right pamphlet.
- How the crew will contain the work area and clean up.
Each company on this site is listed with its phone number where it has one. You can also send a request through the request form.
Rules from the Electronic Code of Federal Regulations and the US Environmental Protection Agency, and state lead programs, checked October 2026.
Sources (8)
- Electronic Code of Federal Regulations: 40 CFR 745.103 ↑
- Electronic Code of Federal Regulations: 40 CFR 745.83 ↑
- Electronic Code of Federal Regulations: 40 CFR 745.82 ↑
- Electronic Code of Federal Regulations: 40 CFR 745.81 ↑
- Electronic Code of Federal Regulations: 40 CFR 745.89 ↑
- Electronic Code of Federal Regulations: 40 CFR 745.85 ↑
- Electronic Code of Federal Regulations: 40 CFR 745.84 ↑
- US Environmental Protection Agency: firm certification ↑